SPECIALIST DEALER
SEARCH

Find your
WAREMA specialist dealer

The calculation of the value for the protection against summer heat includes the total solar energy transmittance gtot for the combination of sun shading system and glazing or the shading factor FC.

The FC value is calculated from the ratio of the total solar energy transmittance of the sun shading system and glazing combination to the g value of the glazing: FC = gtot/g. The calculation of the FC value therefore also always takes the glazing into consideration – for this reason no fixed FC value can be given for a sun shading product.

Outside:

In between:
Inside:
We recommend that you get calculations for the FC and gtot values for your project-specific combination of glazing and sun shading system.

Further information can be found here:

This section contains details about transmittance, reflectance and absorptance in the solar and visual ranges for different sun shading products. In addition, general colour rendering index Ra data are also available:

Outside

When used effectively, sun shading and glare control products can reduce heating energy requirements in winter.

You can find detailed information on the physical effects here.

Top-mounted roller shutters for new buildings, inspection from outside, thermal protection technical data for masonry

Box modelMasonryBox size

Shaft 80
standard
monolithic240x250300x250300x300
365x250365x300
Shaft 80
standard
with exterior insulation240x250300x250
300x300365x250
365x300
Shaft 80
clip system
monolithic240x250300x250
300x300365x250
365x300
Shaft 80
clip system
with exterior insulation240x250300x250
300x300365x250
365x300
Shaft 120
standard
monolithic
300x250
300x300365x250
365x300
Shaft 120
standard
with exterior insulation
300x250
300x300365x250
365x300
Shaft 120
clip system
monolithic
300x250
300x300365x250
365x300
Shaft 120
clip system
with exterior insulation
300x250
300x300365x250
365x300

Top-mounted roller shutters for new buildings, inspection from inside, thermal protection technical data for masonry

Box model
MasonryBox size

Standard
monolithic
240x250
300x250
300x300
365x250
365x300
Standard
with exterior insulation
240x250
300x250
300x300
365x250365x300
Clip system
monolithic

300x250
300x300
365x250
365x300
Clip system
with exterior insulation

300x250
300x300
365x250
365x300

Top-mounted roller shutters for new buildings, inspection from outside, thermal protection technical data for clinker brick


Box modelBox sizes
Shaft 120 clip system300 x 300
365 x 300
Shaft 80 standard300 x 300365 x 300
Shaft 80 clip system300 x 300
365 x 300
Shaft 120 standard300 x 300
365 x 300

Top-mounted roller shutters for new buildings, inspection from inside, thermal protection technical data for clinker brick

Box model
Box size

Standard
240x250
300x250
300x300
Clip system

300x250
300x300

Top-mounted roller shutter, test values for thermal protection and sound insulation

On this page you will find the test values for top-mounted roller shutters AU-RO.
Please note the present structural conditions.
Click on the respective box size in order to display the test documentation.

Thermal protection technical data for AU-RO
MasonryBox size


monolithic172024
with exterior insulation (EIFS)172024

Sound absorbing coefficients for AU-RO
Box modelBox size


Standard172024
Sound insulation 1172024
Sound insulation 2
172024
Note about box models:

Standard = Box model as per technical data
Sound insulation 1 = sound insulation profile incl. brush and sound seal strip
Sound insulation 2 = sound insulation incl. brush and sound absorbing insert

Air density test values
Box size
24
20

Renovation roller shutter, test values for heat transmission coefficient

The detailed basic conditions for determining the test values are provided in the detailed test reports. Please click the respective value.


Test values for the heat transmission coefficient

Box size 205
Box size 225
Temperature factor fRSi (Target: fRSI ≥ 0.70)
0.74
0.73
Heat values USB in W/(m2K) (Target: ≤ USB 0.85)
0.79
0.74

The values specified above only apply in combination with the inspection cover offered as an accessory.

           

Top-mounted roller shutters for new buildings, inspection from outside, sound absorbing coefficients for masonry

Box model
Box size

Shaft 80 standard240x250
300x250
300x300
365x250
365x300
Shaft 80 clip system240x250
300x250
300x300
365x250
365x300
Shaft 120 standard
300x250
300x300
365x250
365x300
Shaft 120 clip system300x250
300x300
365x250
365x300

Top-mounted roller shutters for new buildings, inspection from inside, sound absorbing coefficients for masonry

Box model
Sound insulation packageJoint sealBox size
Standardnone
none
240x250
300x250300x300
365x250365x300
Standardnone
with
240x250
300x250
300x300
365x250
365x300
Standardwithnone
240x250
300x250
300x300
365x250
365x300
Standardwith
with
240x250
300x250
300x300
365x250
365x300
Clip systemnonenone
300x250
300x300
365x250
365x300
Clip systemnone
with
300x250
300x300
365x250
365x300
Clip systemwithnone
300x250
300x300
365x250
365x300
Clip systemwithwith

300x250
300x300
365x250
365x300

Top-mounted roller shutters for new buildings, inspection from outside, sound absorbing coefficients for clinker brick

Box model
Box size
Shaft 80 standard300x300
365x300
Shaft 80 clip system300x300365x300
Shaft 120 standard300x300365x300
Shaft 120 clip system300x300365x300

Top-mounted roller shutters for new buildings, inspection from inside, sound absorbing coefficients for clinker brick

Box model
Sound insulation packageJoint sealBox size
Standardnone
none
240x250
300x250300x300
Standardnone
with
240x250
300x250
300x300
Standardwithnone
240x250
300x250
300x300
Standardwith
with
240x250
300x250
300x300
Clip systemnonenone
300x250
300x300
Clip systemnone
with
300x250
300x300
Clip systemwithnone
300x250
300x300
Clip systemwithwith

300x250
300x300

Top-mounted roller shutter, test values for thermal protection and sound insulation

On this page you will find the test values for top-mounted roller shutters AU-RO.
Please note the present structural conditions.
Click on the respective box size in order to display the test documentation.

Thermal protection technical data for AU-RO
MasonryBox size


monolithic172024
with exterior insulation (EIFS)172024

Sound absorbing coefficients for AU-RO
Box modelBox size


Standard172024
Sound insulation 1172024
Sound insulation 2
172024
Note about box models:

Standard = Box model as per technical data
Sound insulation 1 = sound insulation profile incl. brush and sound seal strip
Sound insulation 2 = sound insulation incl. brush and sound absorbing insert

Air density test values
Box size
24
20

         

Dialux Evo product data

You can get our Dialux Evo product data by calling the Building Physics and Sustainable Building hotline.

Your direct contact to us

Building Physics and Sustainable Building hotline
 Hotline Bauphysik und nachhaltiges Bauen

Hotline Building Physics and Sustainable Building

+49 9391 20-3025

bauphysik@warema.de

* Necessary data to make contact.
I hereby consent to WAREMA saving my contact details